Mifare RFID Hotel Room Card Power Switch HL-E01
Price: US$11.00 – 14.00 / Unit
Product Summary
The Mifare RFID Hotel Room Card Power Switch HL-E01 is a specialized energy-saving switch that works seamlessly with Mifare hotel lock systems. This switch requires a Mifare RFID 13.56 MHz key card to activate the power supply in hotel rooms, ensuring electricity is used efficiently and only when necessary.
This switch promotes efficient energy use and ensures electricity is utilized only when needed. Once the card is removed, the switch automatically cuts off the power after a brief delay of about 15 seconds.
The HL-E01 is highly compatible with most existing MIFARE RFID hotel lock systems, making it a seamless, energy-efficient upgrade for modern hotels.
This switch is ideal for hotels looking to improve their energy management and safety protocols while maintaining compatibility with existing MIFARE systems.
Get Configuration & Quote
Product Details
The hotel room card power switch HL-E01 is engineered explicitly for MIFARE hotel locking systems, offering an innovative solution for energy management and safety in hotel environments. Here’s a detailed look at its key features:
- Energy Efficiency: Capable of saving up to 40% in energy and related costs, this switch encourages substantial energy conservation, directly impacting the hotel’s operational expenses positively.
- Enhanced Safety: Designed to enhance the electrical safety of hotel rooms, the switch automatically cuts off the power supply once the MIFARE RFID key card is removed, ensuring all electrical devices are safely deactivated when not in use.
- Exclusive Compatibility: Operates exclusively with MIFARE RFID cards, ensuring seamless integration with specialized security systems and preventing unauthorized use.
- Ease of Use: Guests can insert their MIFARE key card to activate the room’s power, making it straightforward and user-friendly. The power is automatically disconnected when the card is removed, which is convenient and energy-efficient.
- Simple Installation: The switch is designed for easy installation with no complex wiring or batteries required, allowing for quick setup in any hotel room.
- Durable Design: Features a sleek, robust design engineered to withstand heavy use, making it suitable for high-traffic hotels.
- System Integration: Perfectly integrates with existing MifARE hotel lock systems, creating a cohesive and efficient operational system.
- Customization: This option allows you to customize with a hotel’s logo, aligning with brand identity and enhancing the aesthetic appeal of hotel interiors.
These features make the HL-E01 a practical and effective choice for modern hotels looking to improve energy efficiency, ensure safety, and maintain consistent branding through sophisticated technology.
| Technical Details | |
| Model | HL-E01 |
| Type | Mifare RFID Hotel Room Card Power Switch |
| Lock Size | 86x86x48mm |
| Weight | 0.40kg |
| Material | Flame retardant PC plastic |
| Color | White/Black/Gold |
| Suitable Key Card type | Mifare 13.56Mhz RFID card |
| Working voltage | AC 180V~250V(110V required customize) |
| Electric current | MAX 40A, 40A power relay |
| Maximum load power | 8800W |
| Delayed power-off time | 10-20 seconds |
| Working temperature | -10℃– 60℃ |
| Working humidity | 15~85%RH |
Preparation:
- Ensure Power is Off: Turn off the main power supply to avoid electrical hazards before installing.
Installation Steps:
- Prepare the Installation Site: Confirm that a hole has been adequately prepared on the side of the room door where the switch will be installed. This will accommodate the switch and its components.
- Mounting Box Installation (If Necessary): Use a switch mounting box to assist with the installation. This box will help ensure the switch is installed smoothly and safely. Mount the box in the prepared hole and secure it with screws.
- Remove the Front Panel: Carefully remove the front panel of the HL-E01 switch. This will separate the front panel from the main panel, allowing access to the internal components for wiring.
- Wire the Main Panel: Connect the electrical wires from the room’s devices to the appropriate terminals on the switch according to the wiring diagram provided. Ensure that all connections are secure and correct.
- Install the Main Panel: Place the central panel of the switch into the mounting box. Secure it using the screws provided to ensure it is firmly in place.
- Reattach the Front Panel: Once the central panel is securely installed, replace the front panel to cover the internal components and complete the installation.
Important Notes:
- Avoid Wire Damage: Be careful not to pinch any wires against the relay on the back of the switch during installation, as this can prevent the switch from cutting off power correctly.
- Check Wiring if Power Supplies Without Card: If the switch provides power without a Mifare card inserted, check and ensure all wiring connections are correct and reinstall them if necessary.
- Remove the Card After Testing: Always remove the card after installation testing to avoid dust accumulation in the card slot if the power is turned off.
- Consider an AC Contactor: You should purchase an AC contactor separately to protect the switch from potential damage due to high current loads.
Safety Tips: Always ensure that electrical installations are performed by qualified personnel and adhere to local electrical codes and standards. This guide will help ensure a safe and effective Mifare RFID Hotel Key Card Power Switch HL-E01 installation.
Hotel Room Card Power Switch HL-E01 HL-E01 Video
If you have any questions, please feel free to leave your questions by using the form below!
Not Sure Which Hotel Key Card Swtiches Suits Your Hotel Best?